RESEARCH ARTICLE


Analysis of Circulating System Frictional Pressure Loss in Microhole Drilling with Coiled Tubing



Hou Xuejun*, 1, 2, Zheng Huikai3, Zhao Jian4, Chen Xiaochun4
1 College of Petrol Engineering, Chongqing University of Science and Technology, Chongqing 401331, China
2 Harold Vance Department of Petroleum Engineering, Texas A&M University, College Station, TX, 77840, USA
3 Tianjin Box-ing Science and Technology Engineering Ltd, Offshore Oil Engineering Ltd. of PetroChina, Tianjin 300451, China
4 Engineering Department, Qingdao TaiNeng Gas Co. Ltd, Qingdao 266000, China


Article Metrics

CrossRef Citations:
2
Total Statistics:

Full-Text HTML Views: 430
Abstract HTML Views: 391
PDF Downloads: 1
Total Views/Downloads: 822
Unique Statistics:

Full-Text HTML Views: 266
Abstract HTML Views: 272
PDF Downloads: 1
Total Views/Downloads: 539



© 2009 Xuejun et al;

open-access license: This is an open access article distributed under the terms of the Creative Commons Attribution 4.0 International Public License (CC-BY 4.0), a copy of which is available at: https://creativecommons.org/licenses/by/4.0/legalcode. This license permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

* Address correspondence to this author at the College of Petrol Engineering, Chongqing University of Science and Technology, Chongqing 401331, China; Tel: 023-65023083; E-mails: xuejun_hou_2013@163.com and boxking2013@126.com


Abstract

In microhole drilling (MHD) with coiled tubing (CT), the calculation models of drilling fluid circulating frictional pressure loss (DFCFPL) are studied for different flow regimes of drilling fluid in CT on reel, downhole CT and annulus. Example analysis of DFCFPL for 89mm diameter microhole is conducted, and the relationships among the total DFCFPL, local DFCFPL in CT on reel, downhole CT and annulus are obtained. The smaller the CT diameter is, the higher the local DFCFPL in CT on reel and downhole CT are. The larger the annulus is, the lower the local DFCFPL in annulus is. So the local DFCFPL in CT is dominant in the circulating system. As for the different diameter CT, the total DFCFPL decreases linearly with the well depth increasing. In order to use the hydraulic energy rationally, 73.025mm diameter CT can be used to drill microhole with well depth less than 1000m, 60.325mm diameter CT should be used to drill microhole well depth of which is more than 1500m. This study can provide references for the CT selection and circulating hydraulic energy rational utilization design in MHD.

Keywords: Circulating frictional pressure loss, coiled tubing, drilling fluid.